Skip to main content
Home › Store

Equipment we
stand behind.

We supply the same components we install. Every item here is specified against a measured design — load analysis first, then the hardware that suits it — with warranties coordinated in your name and after-sales support from the team that commissioned it.

Inverters

The component that decides how the system feels.

Hybrid inverter configuration is one of our core technical capabilities. We install what we can service — so the firmware knowledge and the spare parts are both in Cebu.

Row of hybrid inverters and battery cabinets ready for installation

Hybrid inverters

Battery-ready inverters with automatic changeover, configured to your critical load list. The backbone of most systems we turn over.

Single and three-phase
Parallel-capable for larger arrays
Automatic brownout changeover
Quoted per measured design
Wall-mounted grid-tie string inverter with monitoring display

Grid-tie inverters

For sites with a dependable supply and high daytime consumption, where storage would not earn its place in the budget.

Multi-MPPT string inverters
Monitoring included
Commonly mixed with hybrid on site
Quoted per measured design
Wall-mounted hybrid inverter in a commercial electrical room

Commercial & multi-unit configurations

Paralleled inverters and stacked storage for public buildings and commercial sites, wired and labelled for maintainability.

Delivered up to 68 kW
Paralleled hybrid configuration
Full protection coordination
Quoted per measured design
Solar batteries

Storage sized to your critical loads.

We specify lithium iron phosphate for Philippine conditions. Banks are configured, wired and tested before commissioning — not assembled on the roof on the day.

LiFePO4 battery modules

Wall-mounted and stackable. Our residential installations run from 16 kWh up to 64 kWh banks depending on the critical load list.

51.2 V nominal modules
LvTopsun 314 Ah among units deployed
Integrated BMS, expandable
Quoted per measured design

Commercial battery banks

Multi-module banks for commercial complexes and public facilities, with protection, isolation and labelling built into the installation.

32 kWh and 64 kWh banks delivered
Ventilated, serviceable layout
Monitoring assistance included
Quoted per measured design

Battery energy storage systems

Full BESS packages where storage is the primary requirement — specified, procured, installed, tested and commissioned as one scope.

Sized from load analysis
Generator integration available
Commissioning and documentation
Quoted per measured design
Installers in safety vests fitting solar panels on a rooftop
Panels & mounting

Modules and rail, matched to the roof.

Panel selection follows the structural evaluation, not the other way around. Module mass, frame layout and wind loading are confirmed against the roof before we commit to a specification.

Protection & balance of system

The parts that decide whether it lasts.

Cheap protection gear is the most expensive saving on a solar project. These are the components we will not substitute.

AC/DC protection systems

Isolators, fuses and surge protection coordinated across both sides of the inverter — designed in, not added afterwards.

Grounding & lightning protection

Earthing and lightning protection specified for Philippine conditions, because an unprotected array is a very large antenna.

Monitoring & documentation

System monitoring set up at commissioning and complete project documentation handed over with the installation.

Buying guide

Which battery chemistry belongs in a Cebu install?

The cheapest quote on a battery is almost never the cheapest battery. Here is the ten-year arithmetic we show every client who asks.

Swipe the table sideways to compare →

LiFePO4 (what we specify)
Lead-acid AGM
Gel deep-cycle
Upfront cost
Highest
Lowest
Low
Usable depth of discharge
90%
50%
50–60%
Cycle life at that depth
6,000+ cycles
500–800 cycles
900–1,200 cycles
Replacements in 10 years
None expected
3–4 banks
2–3 banks
Tolerance of 32°C+ ambient
Good, with ventilation
Poor — life halves
Moderate
Maintenance
None
Terminal cleaning, equalisation
Periodic checks
Ten-year cost per usable kWh
Lowest
Highest
Middle

Indicative figures for a 10 kWh usable bank cycled daily in a Philippine climate. Real-world results depend on ventilation, depth of discharge and charge discipline.

Delivered configurations

Real systems, real sizes.

Rather than invented package tiers, here are configurations we have actually specified, installed and turned over — a useful benchmark when you are working out roughly where your own site sits.

Swipe the table sideways to compare →

Site
Type
Array
Storage
Location
Private residence
Hybrid
12 kW
16 kWh
Cebu City
Private residence
Hybrid
16 kW
64 kWh
Mandaue City
Commercial complex
Hybrid
24 kW
32 kWh
Minglanilla
Commercial office
Hybrid + grid-tie
29 kW
Configured to load
A.S. Fortuna, Mandaue
Barangay hall
Hybrid
32 kW
64 kWh
Mantuyong, Mandaue
Office building
Hybrid + grid-tie
42 kW
Configured to load
Hernan Cortes, Mandaue
Barangay hall & police station
Hybrid
68 kW
64 kWh
Subangdako, Mandaue

Completed and turned-over Solar Shift installations. Your configuration is determined by load analysis and a site inspection.

How supply works

Specification before purchase order.

We do not publish a price list, because a price without a design is a guess. Tell us the site and the load, and the quote comes back itemised.

Measured first

Load analysis and site inspection determine the component list — so you buy what the system needs, not what is on the shelf.

Quality components

Sourced from trusted manufacturers and suppliers for dependable performance and long-term value.

Warranty coordination

We register and coordinate manufacturer warranties on your behalf, and handle claims if they arise.

Competitive costing

Project costing broken down line by line, so you can see exactly what each part contributes.

Component enquiry

Tell us the site. We will specify the system.

Supply-only or fully installed, residential or commercial — send us your requirement and we will come back with a specification and an itemised quote.